Length ( l ) | 6.000 mm |
Profile weight | 1,8 kg/m |
ETA-approval | |
Fire test report | — |
Thickness ( S ) | 1,5 mm |
Channel cross section | 1,95 cm² |
Moment of inertia ( ly ) | 4,26 cm4 |
Moment of inertia ( lz ) | 6,03 cm4 |
Section modulus ( Wy ) | 2,07 cm³ |
Section modulus ( Wz ) | 2,94 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,56 kN |
Max. recommended static load for 2m length ( Frec ) | 0,54 kN |
Max. recommended static load for 3m length ( Frec ) | 0,24 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962320640 |
Length ( l ) | 2.000 mm |
Profile weight | 2,45 kg/m |
ETA-approval | |
Fire test report | Yes |
Thickness ( S ) | 2,5 mm |
Channel cross section | 3 cm² |
Moment of inertia ( ly ) | 6 cm4 |
Moment of inertia ( lz ) | 8,99 cm4 |
Section modulus ( Wy ) | 2,85 cm³ |
Section modulus ( Wz ) | 4,38 cm³ |
Max. recommended static load for 1m length ( Frec ) | 2,14 kN |
Max. recommended static load for 2m length ( Frec ) | 0,76 kN |
Max. recommended static load for 3m length | — |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4006209922958 |
Length ( l ) | 3.000 mm |
Profile weight | 2,45 kg/m |
ETA-approval | |
Fire test report | Yes |
Thickness ( S ) | 2,5 mm |
Channel cross section | 3 cm² |
Moment of inertia ( ly ) | 6 cm4 |
Moment of inertia ( lz ) | 8,99 cm4 |
Section modulus ( Wy ) | 2,85 cm³ |
Section modulus ( Wz ) | 4,38 cm³ |
Max. recommended static load for 1m length ( Frec ) | 2,14 kN |
Max. recommended static load for 2m length ( Frec ) | 0,76 kN |
Max. recommended static load for 3m length ( Frec ) | 0,34 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4006209773475 |
Length ( l ) | 6.000 mm |
Profile weight | 2,45 kg/m |
ETA-approval | |
Fire test report | Yes |
Thickness ( S ) | 2,5 mm |
Channel cross section | 3 cm² |
Moment of inertia ( ly ) | 6 cm4 |
Moment of inertia ( lz ) | 8,99 cm4 |
Section modulus ( Wy ) | 2,85 cm³ |
Section modulus ( Wz ) | 4,38 cm³ |
Max. recommended static load for 1m length ( Frec ) | 2,14 kN |
Max. recommended static load for 2m length ( Frec ) | 0,76 kN |
Max. recommended static load for 3m length ( Frec ) | 0,34 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4006209775370 |
Length ( l ) | 3.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | — |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,94 kN |
Max. recommended static load for 2m length ( Frec ) | 0,67 kN |
Max. recommended static load for 3m length ( Frec ) | 0,3 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962145397 |
Length ( l ) | 6.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | — |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,94 kN |
Max. recommended static load for 2m length ( Frec ) | 0,67 kN |
Max. recommended static load for 3m length ( Frec ) | 0,3 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962257205 |
Length ( l ) | 2.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | — |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,58 kN |
Max. recommended static load for 2m length ( Frec ) | 0,64 kN |
Max. recommended static load for 3m length | — |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962063066 |
Length ( l ) | 6.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | — |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,58 kN |
Max. recommended static load for 2m length ( Frec ) | 0,64 kN |
Max. recommended static load for 3m length ( Frec ) | 0,28 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962299441 |
Length ( l ) | 2.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | — |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,65 kN |
Max. recommended static load for 2m length ( Frec ) | 0,64 kN |
Max. recommended static load for 3m length | — |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962063097 |
Length ( l ) | 6.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | — |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,65 kN |
Max. recommended static load for 2m length ( Frec ) | 0,64 kN |
Max. recommended static load for 3m length ( Frec ) | 0,28 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962299472 |
Length ( l ) | 2.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,94 kN |
Max. recommended static load for 2m length ( Frec ) | 0,67 kN |
Max. recommended static load for 3m length ( Frec ) | 0,3 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4006209403907 |
Length ( l ) | 3.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,94 kN |
Max. recommended static load for 2m length ( Frec ) | 0,67 kN |
Max. recommended static load for 3m length ( Frec ) | 0,3 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4006209976586 |
Length ( l ) | 6.000 mm |
Profile weight | 2,06 kg/m |
ETA-approval | |
Fire test report | — |
Thickness ( S ) | 2 mm |
Channel cross section | 2,52 cm² |
Moment of inertia ( ly ) | 5,33 cm4 |
Moment of inertia ( lz ) | 7,69 cm4 |
Section modulus ( Wy ) | 2,58 cm³ |
Section modulus ( Wz ) | 3,75 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,94 kN |
Max. recommended static load for 2m length ( Frec ) | 0,67 kN |
Max. recommended static load for 3m length ( Frec ) | 0,3 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4006209976593 |
Length ( l ) | 6.000 mm |
Profile weight | 2,45 kg/m |
ETA-approval | — |
Fire test report | Yes |
Thickness ( S ) | 2,5 mm |
Channel cross section | 3 cm² |
Moment of inertia ( ly ) | 6 cm4 |
Moment of inertia ( lz ) | 8,99 cm4 |
Section modulus ( Wy ) | 2,85 cm³ |
Section modulus ( Wz ) | 4,38 cm³ |
Max. recommended static load for 1m length ( Frec ) | 2,14 kN |
Max. recommended static load for 2m length ( Frec ) | 0,76 kN |
Max. recommended static load for 3m length ( Frec ) | 0,34 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962257229 |
Length ( l ) | 2.000 mm |
Profile weight | 2,45 kg/m |
ETA-approval | — |
Fire test report | Yes |
Thickness ( S ) | 2,5 mm |
Channel cross section | 3 cm² |
Moment of inertia ( ly ) | 6 cm4 |
Moment of inertia ( lz ) | 8,99 cm4 |
Section modulus ( Wy ) | 2,85 cm³ |
Section modulus ( Wz ) | 4,38 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,74 kN |
Max. recommended static load for 2m length ( Frec ) | 0,72 kN |
Max. recommended static load for 3m length | — |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962063073 |
Length ( l ) | 6.000 mm |
Profile weight | 2,45 kg/m |
ETA-approval | — |
Fire test report | Yes |
Thickness ( S ) | 2,5 mm |
Channel cross section | 3 cm² |
Moment of inertia ( ly ) | 6 cm4 |
Moment of inertia ( lz ) | 8,99 cm4 |
Section modulus ( Wy ) | 2,85 cm³ |
Section modulus ( Wz ) | 4,38 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,74 kN |
Max. recommended static load for 2m length ( Frec ) | 0,72 kN |
Max. recommended static load for 3m length ( Frec ) | 0,32 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962299458 |
Length ( l ) | 2.000 mm |
Profile weight | 2,45 kg/m |
ETA-approval | — |
Fire test report | Yes |
Thickness ( S ) | 2,5 mm |
Channel cross section | 3 cm² |
Moment of inertia ( ly ) | 6 cm4 |
Moment of inertia ( lz ) | 8,99 cm4 |
Section modulus ( Wy ) | 2,85 cm³ |
Section modulus ( Wz ) | 4,38 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,82 kN |
Max. recommended static load for 2m length ( Frec ) | 0,72 kN |
Max. recommended static load for 3m length | — |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962063103 |
Length ( l ) | 6.000 mm |
Profile weight | 2,45 kg/m |
ETA-approval | — |
Fire test report | Yes |
Thickness ( S ) | 2,5 mm |
Channel cross section | 3 cm² |
Moment of inertia ( ly ) | 6 cm4 |
Moment of inertia ( lz ) | 8,99 cm4 |
Section modulus ( Wy ) | 2,85 cm³ |
Section modulus ( Wz ) | 4,38 cm³ |
Max. recommended static load for 1m length ( Frec ) | 1,82 kN |
Max. recommended static load for 2m length ( Frec ) | 0,72 kN |
Max. recommended static load for 3m length ( Frec ) | 0,32 kN |
Amount | 1 pcs. |
GTIN (EAN-Code) | 4048962299489 |